Study Documents MED-EL Performance
Editor: The cochlear implant companies are constantly working to
demonstrate the superiority of their device over those of the other
manufacturers, and each seems to claim superiority in some areas. Here's the
latest press release from MED-EL with information on a recent study.
November 2010
~~~~~~~~~~~~~~~~~
A study published in the October 2010 issue of ORL, the Journal for
Oto-Rhino-Laryngology, Head and Neck Surgery, found that only MED-EL users
continued to improve as the listening condition became progressively more
challenging. The study also found that only MED-EL users could still
understand 50 percent of speech, even when noise was presented at levels
louder than speech. Cochlear Implant (CI) systems from MED-EL, Cochlear and
Advanced Bionics were included in the study. The authors were Sabine Haumann,
Thomas Lenarz and Andrea Büchner from the Medical University of Hannover,
Hannover, Germany.
"This study is interesting because, by varying the background noise
level, the authors were attempting to provide a more realistic measure for
performance than studies where the level of presentation is left constant,"
said Darla Franz, MA CCC-A, Director of Education and Corporate
Communications at MED-EL USA. "Looking at 'real-life' hearing environments
can help determine which coding strategies are providing better speech
understanding for our patients."
In this study, the authors applied a method of testing designed to create
a realistic listening situation. Speech Reception Threshold (SRT) is a
measure of how much noise a subject can tolerate and still understand 50% of
speech correctly. The lower the SRT, the better speech perception in noise.
Subjects were tested with an adaptive test regime where the presentation
level of the speech signal roved by +/- 10 dB or +/- 15 dB. The authors
commented that the results as well as the variation in results are more
representative of speech perception in everyday life than results obtained
from fixed-level test methods, where presentation levels are left constant.
Among all participants, SRT value ranged from -3.8 to 12.8 dB for the +/-
10 dB roving condition, with an average SRT of 2.3 dB (standard deviation:
3.6 dB). Speech reception thresholds varied widely between -4.8 and 17.3 dB
with the +/- 15 dB roving condition, where the average SRT was 3.0 (standard
deviation 4.5 dB).
In fixed-setting evaluations, the participants did not show statistically
significant differences in test scores at 10 dB. However, the authors found
significant differences in speech reception threshold between groups using
different devices, particularly when evaluated against the more challenging
environment. The authors reported that users of the Opus 2 processor "showed
significantly lower SRT values for the +/- 15 dB roving condition (mean -1.0
dB) than for the +/- 10 dB roving condition (mean 0.1 dB)."
The study consisted of 55 postlingually deafened adults, who were an
average of 55 years old (range 20-82 years), with a duration of CI use of
3.0 years (range 0.5-12.0 years). The average duration of deafness prior to
surgery was 1.8 years (range 0.0-9.3 years). Only subjects with good
performance in a fixed level test in noise were chosen for participation.
Eleven (11) subjects each were tested with CI systems from MED-EL (Opus 2
processor), Advanced Bionics (Auria or Harmony speech processor), or
Cochlear (Freedom or Esprit 3G speech processor). Subjects were tested using
their normal everyday settings, and no attempts were made to optimize their
fittings for the test method used in the study. Prior to data collection,
subjects were allowed to adjust their processor controls (volume,
sensitivity, depending on the speech processor used) during a practice list
of 10 sentences using 10 dB roving. If subjects did not use any additional
features in the test, then the subjects did also not use these features in
real life - reflecting every-day processor use. Subjects were not prohibited
from enabling additional features on their processor.
The Opus 2 speech processor received FDA approval in April 2008 and is a
part of the MAESTRO(tm) cochlear implant system. MAESTROTM is comprised of
four compatible components of cochlear implants (SONATATI100, PULSARCI100)
and speech processors (OPUS 1, OPUS 2) providing surgeons and candidates the
option of selecting the best possible solution for each individual case. The
combined technical features provide opportunities for both the highest
wearing comfort and the best possible hearing expe
About MED-EL
MED-EL is a pioneer in the field of implantable hearing solutions. The
world's first micro-electronic multi-channel cochlear implant, developed by
Austrian scientists and MED-EL founders Ingeborg and Erwin Hochmair, was
implanted in Vienna in 1977. Since then, MED-EL has set new standards in
hearing implant technologies, developing and manufacturing technologically
advanced hearing solutions for people with varying degrees of hearing loss.
MED-EL hearing implant systems, currently used in almost 100 countries,
combine the latest scientific advances, engineering and manufacturing
techniques for performance, safety and reliability. MED-EL offers the
broadest portfolio of hearing implant systems, including the MAESTRO CI
system for those with severe-to-profound sensorineural hearing loss and the
unique Vibrant Soundbridge®, a middle ear prosthesis for the
treatment of moderate to severe sensorineural hearing loss. Consistently
high levels of investment in research and development fuel the pipeline of
innovative hearing implant solutions ensuring the company’s dynamic future.
For more information, visit www.medel.com or call 888-MED-EL-CI
(633-3524).